文章詳情
記錄紙B9565AW的誕生
日期:2024-11-24 18:32
瀏覽次數(shù):1054
摘要:
記錄紙B9565AW的誕生
折疊記錄紙是日本橫河在1951年發(fā)明的,也是世界上的**款折疊型記錄紙,它是當(dāng)時(shí)日本橫河開(kāi)發(fā)經(jīng)理Arima先生想到的,它的靈感來(lái)自于佛教規(guī)范** “經(jīng)”的形狀。記錄紙B9565AW的誕生
記錄紙讓用戶在記錄儀記錄數(shù)據(jù)的同時(shí)查看數(shù)據(jù),在工業(yè)自動(dòng)化領(lǐng)域如電廠、化工廠等在記錄數(shù)量的監(jiān)控過(guò)程起了**性的作用。到了1970年代,折疊記錄紙?jiān)谌毡緩V泛應(yīng)用于大多數(shù)記錄儀,成為全球性生產(chǎn)記錄儀廠商的標(biāo)準(zhǔn)。
1985年,日本橫河引進(jìn)了**臺(tái)結(jié)合了微處理筆式記錄儀μR100。有著14x144mm 的標(biāo)準(zhǔn)...
記錄紙B9565AW的誕生
折疊記錄紙是日本橫河在1951年發(fā)明的,也是世界上的**款折疊型記錄紙,它是當(dāng)時(shí)日本橫河開(kāi)發(fā)經(jīng)理Arima先生想到的,它的靈感來(lái)自于佛教規(guī)范** “經(jīng)”的形狀。記錄紙B9565AW的誕生
記錄紙讓用戶在記錄儀記錄數(shù)據(jù)的同時(shí)查看數(shù)據(jù),在工業(yè)自動(dòng)化領(lǐng)域如電廠、化工廠等在記錄數(shù)量的監(jiān)控過(guò)程起了**性的作用。到了1970年代,折疊記錄紙?jiān)谌毡緩V泛應(yīng)用于大多數(shù)記錄儀,成為全球性生產(chǎn)記錄儀廠商的標(biāo)準(zhǔn)。
1985年,日本橫河引進(jìn)了**臺(tái)結(jié)合了微處理筆式記錄儀μR100。有著14x144mm 的標(biāo)準(zhǔn)尺寸,μR100的微處理器可接收來(lái)自于熱電偶或RTD(電阻溫度探測(cè)器)傳感器的自動(dòng)線性化信號(hào),把輸入信號(hào)縮放比例和轉(zhuǎn)換成物理值,柱狀圖和數(shù)值數(shù)據(jù)顯示在一個(gè)內(nèi)置的液晶屏上。它還使打印輸出的測(cè)量數(shù)據(jù)、單位、時(shí)間和測(cè)量指標(biāo)等數(shù)據(jù)劃在記錄紙上。記錄紙B9565AW的誕生
可以說(shuō)沒(méi)有B9565AW折疊紙,就沒(méi)有筆式記錄儀μR100的國(guó)際性成功。B9565AW是由日本橫河電氣和KOKUSAI公司共同開(kāi)發(fā)的。Z-fold記錄紙的應(yīng)用使操作員在記錄儀測(cè)量的整個(gè)過(guò)程中隨時(shí)可以看到記錄的數(shù)據(jù)。隨著質(zhì)量的改善,記錄紙可以耐溫耐濕,長(zhǎng)度也是原長(zhǎng)度的兩倍,只需要每月替換一次記錄紙就行了。
當(dāng)使用劣質(zhì)記錄紙時(shí),會(huì)出現(xiàn)如卡紙 、墨水涂污、印跡模糊和撕裂穿孔等問(wèn)題的發(fā)生。這些故障經(jīng)常被誤以為是儀器故障。這不僅僅是用戶的一個(gè)難題,同時(shí)它也是儀器制造商的一個(gè)負(fù)擔(dān)。
在100毫米記錄儀中使用長(zhǎng)度為原長(zhǎng)度兩倍的折疊記錄紙, 是一個(gè)具有風(fēng)險(xiǎn)性的決定。在μR100的開(kāi)發(fā)階段,測(cè)試了各種圖表制造商提供的記錄紙。這些記錄紙都耐不了日本和其他亞洲國(guó)家的高濕度和溫度,因此不符合日本橫河的嚴(yán)格質(zhì)量控制(QC)標(biāo)準(zhǔn)。
終于,在橫河、KOKUSAI的努力的合作下,一個(gè)*好質(zhì)量的記錄紙被開(kāi)發(fā)出來(lái)并且應(yīng)用于μR100筆式記錄器。B9565AW既是橫河的高質(zhì)量標(biāo)準(zhǔn)產(chǎn)品,又是KOKUSAI為其記錄紙和加工技術(shù)領(lǐng)域上的奉獻(xiàn)。
自此,B9565AW是**推薦用于橫河100毫米有效記錄長(zhǎng)度記錄儀(μR100,μR1000,μR10000,μRS1000)的記錄紙。B9565AW現(xiàn)在是行業(yè)中的標(biāo)準(zhǔn),也是全球使用*為廣泛的記錄紙。
記錄紙B9565AW的誕生
The birth of B9565AW
Z-fold chart paper was first invented by Japanese Yokogawa, and it is also the first kind of z-fold chart paper in the world. It was come to mind by Mr.Arima, the development manager in Japanese Yokogawa. It was inspired by the Buddhist normal scriptures "Ching" shape.
Chart paper can let users check the data when they are using the recorder for recording data. In the field of industrial automation, such as power plants, chemical plants and so on, it plays a revolutionary role in the process of monitoring the number of records. By the 1970s, chart paper had been widely used in a lot of recorders in Japan, becoming the standard of global producer of recorders instrument manufacturers.
In 1985, Japanese Yokogawa introduced a first recorderμR100, combining microprocessor with a pen. It has a standard size of 14x144mm. The microprocessor of μR100 can receive automatic linear signal from thermocouple or RTD (resistance temperature detectors) sensor, which can display the input signal scaling, converted physical values, histogram and numerical data on a built-in LCD screen. It also enables drawing the printout of measurement data, unit, time, measure and other data on a recording sheet.
It can be said that there will be no international success of pen recorder μR100 without z-fold chart paper B9565AW. B9565AW is jointly developed by Japanese Yokogawa Electric and KOKUSAI. The application of Z-fold chart paper can make the operator see the recording data at any time during the process of recorder measurement. With the improvement of the quality, chart paper can be able to bear high temperature and humidity. And the length is twice as much as the original length so that you just need to change the chart paper once a month.
When using poor quality recording paper, it will appear some problems such as paper stuck, ink smears, blot blur and tearing perforation. These failures are often mistaken as instrument malfunction. This is not only a problem for the users, but also a burden for the meter manufacturer.
It is a risky decision using fold recording paper, whose length is twice as the original length, in 100mm recorder. In the developing stages of μR100, it has tested a variety of chart recording paper provided by the manufacturers.
Finally, with Yokogawa and KOKUSAI’s cooperative efforts, the best quality of recording paper has been developed and applied in pen recorderμR100. B9565AW is high quality standard products of Yokogawa as well as making contribution to KOKUSAI recording paper and the field of processing technology.
Since then, B9565AW is the only recording paper recommended for applying in the recorder of 100mm Yokogawa effective recording length (μR100,μR1000,μR10000,μRS1000). B9565AW is now the standard in the industry, but also the world’s most widely used recording paper.
記錄紙B9565AW的誕生